Tag Archives: cx3

Does EMC FASTCache work with Exchange?

Posted on by

Short Answer: Yes!

In my dealings with customers I’ve been requesting performance data from their storage systems whenever I can to see how different applications and environments react to new features. Today I’m going to give you some more real-world data, straight from a customer’s production EMC NS480.

I’ve pulled various stats out of Analyzer for this customer’s Exchange server, which has 3 mail databases totaling about 1TB of mail stored on the NS480 via FibreChannel connect. Since this customer is not extremely large (similar to most of our customers) they are using this NS480 for pretty much everything from VMWare, SQL, and Exchange, to NAS, web/app content, and Business Intelligence systems. There is about 30TB of block data and another 100TB of NAS data. FASTCache is enabled for all LUNs and Pools with just 183GB of usable FASTCache space (4 x 100GB SSDs). So in this environment, with a modest amount of FASTCache and very mixed workload, how does Exchange fare?

Let’s first take a look at the Exchange workload itself for a 24 hour period: (Note: There were no reads from the Exchange log LUNs to speak of so I left that out of this analysis.)

Total Read IOPS for the 3 databases: (the largest peak is a result of database maintenance jobs and the smaller peaks are due to backup jobs) Here it’s tough to see due to the maintenance and backup peaks, but production IO during the work day is about 200-400IOPS. By the way, a source-deduplicating incremental-forever backup technology, such as Avamar, could drastically reduce the IO Load and duration of the nightly backup

Total Write IOPS for the 3 databases: Obviously more changes to the database occurring during the work day.

Total Write IOPS for the 3 Log files: Log data is typically cached easily in the SP cache so FAST Cache isn’t terribly required here but I’m including it to show whether there is any value to using FASTCache with Exchange logs.

Now let’s look at the FASTCache hit ratios for this same set of data: (average of all 3 DBs)

First, the Read Activity: Here you can see that aside from the maintenance and backup jobs, FASTCache is servicing 70-90% of the Read IOPs. Keep in mind that a FASTCache miss could still be a Cache Hit if the data is in SP Cache. What’s interesting about this is that it looks like the nightly maintenance job is pushing the highest load.

And the Write Activity: The beauty of EMC’s FASTCache implementation being a read/write cache, the benefit extends beyond just read IO. Here you see that FASTCache is servicing 60-80% of the writes for these Exchange Databases. That’s a huge load off the backend disks.

And the Log Writes: Since Log writes are usually not a performance problem, I would say that FASTCache is not necessary here, and the average 30% hit ratio shown here is not great. If you wanted to spend the time to tune FASTCache a bit, you might consider disabling FASTCache for Log LUNs to devote the FASTCache capacity to more cache friendly workloads.

All in all you can see that for the database data, FASTCache is servicing a significant portion of the user generated workload, reducing the backend disk load and improving overall performance.

Hopefully this gives you a sense of what FASTCache could do for your Exchange environment, reducing backend disk workload for reads AND writes. I must reiterate, since an SP Cache hit is shown as a FASTCache miss, an 80% FASTCache hit ratio does not mean that 20% of the IOs are hitting disk. To illustrate this, I’ve graphed the sum of SP Cache Hits and FAST Cache Hits for a single database. You can see that in many cases we’re hitting a total of 100% cache hits.

Most interesting is the backup window where SP Cache is really handling a huge amount of the load. This is actually due to the Prefetch algorithms kicking in for the sequential read profile of a backup, something CX/VNX is very good at.

Find your busiest LUNs Fast with Unisphere Analyzer Search

Posted on by

One of the features that has been added to Analyzer (Navisphere and Unisphere) in recent versions is the ability to search for specific LUNs based on criteria.  This feature is actually pretty powerful because the criteria itself is pretty flexible.  For example, you can search for all LUNs attached to a specific host, or with a specific set of characters in the LUN name.  In addition you can search against performance metrics like Throughput, Response Time, or LUN Utilization.  This is where it gets interesting because you can look for poorly performing LUNs really quickly.  In the following example, I am going to build a search that looks for LUNs that have EX in the name (since all of my Exchange server LUNs have EX in the name) that ALSO have high LUN utilization for several polling intervals.

Once you’ve launched Analyzer and opened an Archive, click on the binocular icon in the tool bar to bring up the search dialog. 

You can choose a predefined search (a search you previously created and saved) or a new Object Based Query.  In this example we are going to build a new query so select “Object Based Query” and choose All LUNs in the drop down box.  If you wanted, you could narrow down the search to just Pool Based LUNs, just MetaLUNs, or Component LUNs, etc.)

Next we’ll define the LUN criteria by selecting the Name property, choosing Contains, and entering the “EX” value.  This will filter the search to only those LUNs that have EX in the name.  Finally we’ll set a threshold.  In this example, I’m looking for LUNs that have a LUN Utilization value over greater than 90% for at least 10 polling samples.  I could add more LUN criteria and/or more thresholds to further narrow down the results with AND or OR combinations.

Optionally, you can save the query so that it will be listed in the “Predefined Query” list in the future.  Click Search and set or edit the name of the search.

After clicking OK, Analyzer will create a new tab and populate the results of the search.  Once the search is complete you can graph metrics for the LUNs like normal.  Here I’ve selected Utilization to show why this LUN matched the search criteria — note the high utilization between 2am and 7am.

You can get much more granular with your searches if you are looking for something specific, or use metrics like Response Time to look for poorly performing LUNs attached to a specific server.  It’s pretty flexible.  I started using the search feature recently and thought others might be interested in it.  Try it out and let me know what you think.

Performance Analysis for Clariion and VNX – Part 5 (FASTCache)

Posted on by

<< Back to Part 4 — Part 5 — Go to Part 6 >>

Sorry for the delay on this next post..  Between EMC World and my 9 month old, it’s been a battle for time…

Okay, so you have an EMC Unified storage system (Clariion, Celerra, or VNX) with FASTCache and you’re wondering how FASTCache is helping you.  Today I’m going to walk you through how to tease FASTCache performance data out of Analyzer.

I’m assuming you already have Analyzer launched and opened a NAR archive.  One thing to understand about Analyzer stats as they relate to FASTCache, is that stats are gathered at the LUN level for traditional RAID Group LUNs, but for Pool based LUNs, the stats are gathered at the pool level.  As a result graphing data for FASTCache differs for the two scenarios.

First we’ll take a look at the overall array performance.  Here we’ll see how much of the write workload is being handled by FASTCache.  In the SP Tab of Analyzer, select both SPs (be sure no LUNs or other objects are selected).  Select Write Throughput (IO/s), and then click the clipboard icon (with I’s and O’s).

Launch Microsoft Excel and paste into the sheet, and then perform the text-to-column change discussed in the previous post if necessary.

Next create a formula in the D column, adding the values for both SPs into a single total.  We’re not going to graph it quite yet though.

Back in Analyzer, deselect the two SPs, switch to the Storage Pool Tab, right-click on the array and choose Select All -> LUNs, then Select All -> Pools.

Click on a RAID Group LUN or Pool in the tree, it doesn’t matter which one, deselect Write Throughput (IO/s) and select FAST Cache Write Hits/s.  In a moment, you’ll end up with a graph like this.

Click the clipboard icon again to copy this data and paste it into a new sheet of the same workbook in Excel.  Insert a blank column between column A and B, then create a formula to add the values from column B through ZZ (ie: =SUM(C2:ZZ2).

Then copy that formula and paste into every row of column B.  This column will be our Total FAST Cache Write Hits for the whole array.  Finally, click the header for Column B to select it, then copy (CTRL-C).  Back to the first sheet — Paste the “Values” (123 Icon) into Column E.

Now that we have the Total Write IOPS and Total FAST Cache Write Hits in adjacent columns of the same worksheet, we can graph them together.  Select both columns (D and E in my example), click Insert, and choose 2D Area Chart.  You’ll get a nice little graph that looks something like the following.

Since it’s a 2D Area Chart, and not a stacked graph, the FASTCache Write IOPS are layered over the Total Write IOPS such that visually it shows the portion of total IOPS handled by FASTCache.  Follow this same process again for Read Throughput and FASTCache Read Hits.  Furthur manipulation in Excel will allow you to look at total IOPS (read and write) or drill down to individual Pools or RAID Group LUNs.

Another thing to note when looking at FASTCache stats…  FAST Cache Misses are IOPS that were not handled by FASTCache, but they may still have been handled by SP Cache.  So in order to get a feel for how many read IOs are actually hitting the disks, you’d actually want to subtract SP Read Cache Hits and Total FASTCache Read Hits (calculated similar to the above example) from SP Read Throughput.  This is similar for Write Cache Misses as well.

I hope this helps you better understand your FASTCache workload.  I’ll be working on FASTVP next, which is quite a bit more involved.

<< Back to Part 4 — Part 5 — Go to Part 6 >>

Performance Analysis for Clariion and VNX – Part 4

Posted on by

<< Back to Part 3 — Part 4 — Go to Part 5 >>

Making Lemonade from Lemons.

In the last post, we looked at the storage processor statistics to check for cache health, excessive queuing, and response time issues and found that SPA has some performance degradation which seems to be related to write IO.  Now we need to drill down on the individual LUNs to see where that IO is being directed.  This is done in the LUN tab of Analyzer.  First, right click on the storage array itself in the left pane and choose deselect all -> items.  Then click the LUN tab and right click on the top level of the tree “LUNs”, choose select all -> LUNs.  Click on one of the LUNs to highlight it, then in choose Write Throughput (IO/s) from the bottom pane.  It may take a second for Analyzer to render the graph but you’ll end up with something like this…

You’ll quickly realize that this view doesn’t really help you figure out what’s going on.  With many LUNs, there is simply too much data to display it this way.  So click the clipboard button that has the I’s and O’s in it (next to the red arrow) to copy the graph data (in CSV format) into your desktop clipboard.  Now launch Microsoft Excel, select cell A1 and type Ctrl-V to paste the data.  It will look like the following image at first, with all LUNs statistics pasted into Column A.

Now we need to break out the various metrics into their own columns to make meaningful data, so go to the Data menu and click Text to Columns (see red arrow above).  Select Delimited, click Next..  Select ONLY comma as the delimiter, then next, next, finish.  Excel will separate the data into many columns (one column per LUN).  Next we’ll create a graph that can actually tell us something.  First, click the triangle button at the upper left corner of the sheet to select all of the data in the sheet at once.  Then click the area chart icon, select Area, then the Stacked Area (see Red Arrows below) icon.  Click OK.

You’ll get a nice little graph like this one below that is completely useless because the default chart has the X and Y axis reversed from what we need for Analyzer data.

To Fix this, right click on the graph, choose “Select Data”, click the Switch row/column button, and click OK.

Now you have a useful graph like the one below.  What we are seeing here is each band of color representing the Write IOPS for a particular LUN.  You’ll note that about 6 LUNs have very thick bands, and the rest of the over 100 LUNs have very small bands.  In this case, 6 LUNs are driving more than 50% of the total write IOPS on the array. Since the column header in the Excel sheet has the LUN data, you can mouse over the color band to see which LUN it represents.

Now that you know where to look, you can go back to Analyzer, deselect all LUNs and drill down to the individual LUNs you need to look at.  You may also want to look at the hosts that are using the busy LUNs to see what they are doing.  In Analyzer, check the Write IO Size for the LUNs you are interested in and see if the size is in line with your expectations for the application involved. Very large IO sizes coupled with high IOPS (ie: high bandwidth) may cause write cache contention.  In the case of this particular array, these 6 LUNs are VMFS datastores, and based on the Thin LUN space utilization and write IO loads, I would recommend that the customer convert them from Thin LUNs to Thick LUNs in the same Virtual Pool.  Thick LUNs have better write performance and lower processor overhead compared with Thin LUNs and the amount of free space in these Thin LUNs is fairly small.  This conversion can be done online with no host impact using LUN Migration.

You can use this copy/paste technique with Excel to graph all sorts of complex datasets from Analyzer that are pretty much not viewable with the default Analyzer graph.  This process lets you select specific data or groups of metrics from an complete Analyzer archive and graph just the data you want, in the way you want to see it.  There is also a way to do this as a bulk export/import, which can be scheduled too, and I’ll discuss that in the next post.

<< Back to Part 3 — Part 4 — Go to Part 5 >>

Performance Analysis for Clariion and VNX – Part 3

Posted on by

<< Back to Part 2 — Part 3 — Go to Part 4 >>

Disclaimer: Performance Analysis is an art, not a science.  Every array is different, every application is different, and every environment has a different mix of both.  These posts are an attempt to get you started in looking at what the array is doing and pointing you in a direction to go about addressing a problem.  Keep in mind, a healthy array for one customer could be a poorly performing array for a different customer.  It all comes down to application requirements and workload.  Large block IO tends to have higher response times vs. small block IO for example.  Sequential IO also has a smaller benefit from (and sometimes can be hindered by) cache.  High IOPS and/or Bandwidth is not a problem, in fact it is proof that your array is doing work for you.  But understanding where the high IOPS are coming from and whether a particular portion of the IO is a problem is important.  You will not be able to read these series of posts and immediately dive in and resolve a performance problem on your array.  But after reading these, I hope you will be more comfortable looking at how the system is performing and when users complain about a performance problem, you will know where to start looking.  If you have a major performance issue and need help, open an case.

Starting from the top…

First let’s check the health of the front end processors and cache.  The data for this is in the SP Tab which shows both of the SPs.  The first thing I like to look at is the “SP Cache Dirty Pages (%)” but to make this data more meaningful we need to know what the write cache watermarks are set to.  You can find this by right-clicking on the array object in the upper-left pane and choosing properties.  The watermarks are shown in the SP Cache tab.

Once you note the watermarks, close the properties window and check the boxes for SPA and SPB.  In the lower pane, deselect utilization and chose SP Cache Dirty Pages (%).

Dirty pages are pages in write cache that have received new data from hosts, but have not been flushed to disk.  Generally speaking you want to have a high percentage of dirty pages because it increases the chance of a read coming from cache or additional writes to the same block of data being absorbed by the cache.  Any time an IO is served from cache, the performance is better than if the data had to be retrieved from disk.  This is why the default watermarks are usually around 60/80% or 70/90%.


What you don’t want is for dirty pages to reach 100%.  If the write cache is healthy, you will see the dirty pages value fluctuating between the high and low watermarks (as SPB is doing in the graph).  Periodic spikes or drops outside the watermarks are fine, but repeatedly hitting 100% indicates that the write cache is being stressed (SPA is having this issue on this system).  The storage system compensates for a full cache by briefly delaying host IO and going into a forced flushing state.  Forced Flushes are high priority operations to get data moved out of cache and onto the back end disks to free up write cache for more writes.  This WILL cause performance degradation.  Sustained Large Block Write IO is a common culprit here.

While we’re here, deselect Dirty Pages (%) and select Utilization (%) and look for two things here:

1.) Is either SP running at a load of higher than 70%?  This will increase application response time.  Check whether the SPs seem to fluctuate with the business day.  For non-disruptive upgrades, both SPs need to be under 50% utilization.

2.) Are the two SPs balanced?  If one is much busier than the other that may be something to investigate.

Now look at Response time (ms) and make sure that, again, both SPs are relatively even, and that Response time is within reasonable levels.  If you see that one SP has high utilization and response time but the other SP does not, there may be a LUN or set of LUNs owned by the busy SP that are consuming more array resources.  Looking at Total Throughput and Total Bandwidth can help confirm this, and then graphing Read vs. Write Throughput and Bandwidth to see what the IO operations actually are.  If both SPs have relatively similar throughput but one SP has much higher bandwidth, then there is likely some large block IO occurring that you may want to track down.

As an example, I’ve now seen two different customers where a Microsoft Sharepoint server running in a virtual machine (on a VMFS datastore) had a stuck process that caused SQL to drive nearly 200MB/sec of disk bandwidth to the backend array.  Not enough to cause huge issues, but enough to overdrive the disks in that LUN’s RAID Group, increasing queue length on the disks and SP, which in turn increased SP utilization and response time on the array.  This increased response time affected other applications unrelated to Sharepoint.

Next, let’s check the Port Queue Full Count.  This is the number of times that a front end port issued a QFULL response back to the hosts.   If you are seeing QFULL’s there are two possible causes.. One is that the Queue Depth on the HBA is too large for the LUNs being accessed.  Each LUN on the array has a maximum queue depth that is calculated using a formula based on the number of data disks in the RAID Group.  For example, a RAID5 4+1 LUN will have a queue depth of 88.  Assuming your HBA queue depth is 64 then you won’t have a problem.  However, if the LUN is used in a cluster file system (Oracle ASM, VMWare VMFS, etc) where multiple hosts are accessing the LUN simultaneously, you could run into problems here.  Reducing the HBA Queue Depth on the hosts will alleviate this issue.

The second cause is when there are many hosts accessing the same front end ports and the HBA Execution Throttle is too large on those hosts.  A Clariion/VNX front end port has a queue depth of 1600 which is the maximum number of simultaneous IO’s that port can process.  If there are 1600 IOs in queue and another IO is issued, the port responds with QFULL.   The host HBA responds by lowering its own Queue Depth (per LUN) to 1 and then gradually increasing the queue depth over time back to normal.  An example situation might be 10 hosts, all driving lots of IO, with HBA Execution Throttle set to 255.  It’s possible that those ten hosts can send a total of 2550 IOs simultaneously.  If they are all driving that IO to the same front end port, that will flood the port queue.  Reducing the HBA Execution throttle on the hosts will alleviate this issue.

Looking at the Port Throughput, you can see here that 2 ports are driving the majority of the workload.  This isn’t necessarily a problem by itself, but PowerPath could help spread the load across the ports which could potentially improve performance.

In VMWare environments specifically, it is very common to see many hosts all accessing many LUNs over only 1 or 2 paths even though there may be 4 or 8 paths available.  This is due to the default path selection (lowest port) on boot.  This could increase the chances of a QFULL problem as mentioned above or possibly exceeding the available bandwidth of the ports.  You can manually change the paths on each LUN on each host in a VMWare cluster to balance the load, or use Round-Robin load balancing.  PowerPath/VE automatically load balances the IO across all active paths with zero management overhead.

Another thing to look for is an imbalance of IO or Bandwidth on the processors.  Look specifically at Write Throughput and Write Bandwidth first as writes have the most impact on the storage system and more specifically the write cache.  As you can see in this graph, SPA is processing a fair bit more write IOPS compared to SPB.  This correlates with the high Dirty Pages and Response Time on SPA in the previous graphs.

So we’ve identified that there is performance degradation on SPA and that it is probably related to Write IO.  The next step is to dig down and find out if there are specific LUNs causing the high write load and see if those could be causing the high response times.

<< Back to Part 2 — Part 3 — Go to Part 4 >>

Performance Analysis for Clariion and VNX – Part 2

Posted on by 11 comments

<< Back to Part 1 — Part 2 — Go to Part 3 >>

Okay, so you’ve got the Analyzer enabler on your array and enabled logging, and you’ve installed Unisphere Server, Unisphere Client, and Microsoft Excel on your workstation.  Next step is to download a NAR file from the array.  In Navisphere, right click on the array, go to the Analyzer menu and retrieve an archive.  You can get the archive from either SP of the array, both have the same data.  You will eventually see multiple NAR files, each covering some period of time.  Retrieve the one for the period of time you want to look at.  You can also merge multiple files together to get larger time periods into a single analyzer session.  In Unisphere, the process is essentially the same, select the array, go to Monitoring -> Analyzer.

You’ve got your workstation set up and you have a NAR file downloaded to your workstation.  Let’s get to it.  Launch Unisphere Client from the Start Menu and connect to “localhost” when prompted.  Login to Unisphere.  You’ll see something like this…

In the drop down menu change to the “Unisphere Server – 127.0.0.1” which will change the main screen to Event Notification most likely.  Click on Monitoring, then Analyzer.

Let’s set some defaults before we open a NAR file.

  1. In the left pane, click Customize Charts
    1. In the General Tab, check the Advanced box so we can see more detailed metrics in Analyzer
    2. In the Archive Tab, under Analyzer, select Performance Detail and make sure Initially Check All Tree Objects is unchecked.
  1. Click OK to save.

In the right pane, click on Open Archive , browse to the NAR file you want to view and open.

Because the NAR file can contain many hours (sometimes multiple days) or performance data, you will be prompted to set a time range.  The default times will show all data available in the archive.  If you want to narrow down to a smaller time range, change the Graph Start and End times, otherwise just click OK.

The Performance Detail window will launch and the LUN tab will be selected.  No items should be selected and as such no data will be graphed.

My personal methodology is to take a top-down approach when it comes to performance analysis and troubleshooting.

  • Check the SP’s, Cache, and SP Ports for obvious issues.  If a user is complaining of poor performance the Cache is usually the first place I look.
  • Drill down to RAID Groups, Pools, and LUNs to find the culprits
  • Drill down to the physical disk level if necessary
  • Export data to Excel for better graphs that make it easier to see whats happening

<< Back to Part 1 — Part 2 — Go to Part 3 >>

Performance Analysis for Clariion and VNX – Part 1

Posted on by
Part 1 — Go to Part 2 >>
  • Do you have an application owner complaining about performance?
  • Do you want to get a general idea of how your array is performing?
  • Do you want to turn this.. into this..?

I’ve been doing a lot of performance analysis with EMC Clariion CX3, CX4, and VNX storage recently and have a sort of an informal methodology I follow.  I’ve had a couple customers ask me to show them how to get useful data and graphs from their arrays and more recently after posting about FASTCache and FASTVP results I’ve had even more queries on the topic.  So I’ve decided to put together a sort of how-to guide.  It will take several posts to go through the whole process, so this first post will focus on making sure you have the right tools. The Tools: First, you MUST have the Navisphere/Unisphere Analyzer enabler on the storage array.  If you don’t have it, all you can really do is send an encrypted archive to EMC for help when you have a performance problem.  Analyzer is an indispensable performance analysis tool for CX/VNX systems and is really quite powerful.  Unfortunately, many customers don’t see the value during the purchase process but end up needing it someday in the future.  Make sure Analyzer is included in EVERY array purchase.

If you haven’t already, you also need to enable Statistics on the array AND in more recent versions of FLARE you need to enable Archive Logging.  Statistics logging is enabled in the array properties dialog, shown here…

Archive Logging is enabled in the Monitoring -> Analyzer -> Data Logging dialog, shown here…

In practice, 5 minutes is a good interval for archives.  Also make sure that periodic archiving is enabled which will generate a new NAR file every so often (it depends on the interval)

Next, you need an Analyzer workstation.  You can run Analyzer directly off an array through Navisphere Manager or Unisphere but I prefer installing the software directly on my PC.  It lets me work on the analysis from home or anywhere else, and since I look at data from many different customer’s arrays’ it’s easier.  You can download the latest version of Unisphere Server and Unisphere Client directly from PowerLink (Home > Support > Software Downloads and Licensing > Downloads T-Z > Unisphere Server Software).  Once you install both, you can launch the client and log in to your local Unisphere server.   You can then open Analyzer archive files (NAR files) from any array for analysis. Third, you need a graphing tool.  I currently use Microsoft Excel 2010 on the same workstation as my Unisphere installation, which happens to be my corporate laptop.  While Analyzer does graph the data you select, there is only one type of graph available and sometimes when many objects are being graphed together it’s almost impossible to actually compare them to each other.

Another reason to use Excel is that while Analyzer has a wealth of different statistics available for all sorts of array objects, there are some exceptions right now.  For example, if you are using newer features such as FASTCache or FASTVP on your array and want to see statistics for those technologies, there is not much in Analyzer to see.  I’ll go through some methods for teasing that data out as well.

Part 1 — Go to Part 2 >>

Simplify Storage Management Today, Risk Free, and Free of Charge

Posted on by

While my peers have been blogging about the new CLARiiON and Celerra releases, both of which provide significant enhancements to the EMC CX4-based Unified platforms you already own, I thought I’d shift gears just a tad…

What if you are a Clariion CX/CX3 customer, or a CX4 customer who isn’t ready to upgrade to the newly released FLARE30 code, but want to simplify management of your storage environment, get better reporting, dashboards, wizards, etc.  Well, you are in luck.

Just as with previous versions of Navisphere and FLARE, EMC offers off-array versions of Clariion management agents, servers, and GUIs.  As of yesterday, that includes off-array versions of Unisphere.  If you are a current customer of Clariion, you can login to PowerLink and download the Unisphere off-array software and build a management station.  After installation, you can manage your existing Clariion CX/CX3/CX4 hardware without upgrading the FLARE code.  As you upgrade your CX4 systems to FLARE30, new features will be enabled in Unisphere, and as you upgrade your Celerra NS systems to DART6, they can be added to the Clariion management domain and managed from the very same Unisphere instance.  How’s that for easy and convenient?

But what do you get by using Unisphere to manage your non-FLARE30 systems?  Unfortunately, you won’t be able to take advantage of FASTCache, FAST, Compression, and other features that are only available in FLARE 30, but there are some advantages..

First and foremost, Unisphere completely dumps the Navisphere tree-based management view and replaces it with end-result based tasks.  So instead of creating several objects to provision raid groups and LUNs, then present to a host, you just run the “Allocate” wizard and select the array, disks/raid group/pool, LUN size, hosts, etc and commit.

Second, upon launching Unisphere and logging in, you are immediately presented with dashboard views showing the amount of used/available storage, and active alerts, all customizable, so you can see the state of your entire CLARiiON storage environment “at-a-glance”.

To install Unisphere today, login to Powerlink, browse to “Support > Software Downloads and Licensing > Downloads T-Z > Unisphere Server Software” and download “EMC Unisphere Server” and “EMC Unisphere Client”.  Install them both to your Windows system and fire it up.  If you have Navisphere off-array software already installed, Unisphere will upgrade the existing installation for you.  You will also want to download and install Unisphere Service Manager (USM), also from Powerlink at “Support > Software Downloads and Licensing > Downloads T-Z > Unisphere Service Manager (USM).”  USM will provide various support and service related tools including active technical advisories for your storage arrays.

Begin using Unisphere today and you get some immediate benefits, plus you will be ready to take advantage of new features enabled with FLARE30 (FAST, FASTCache, Compression, etc) as well as managing NAS across all of your Celerra systems once they are upgraded to DART 6.  As a bonus, you’ll have a chance to get familiar with Unisphere before a future FLARE upgrade or new EMC Unified purchase forces you to learn it.

And did I mention you don’t have to buy anything or introduce risk with a firmware upgrade?

While EMC users benefit from Replication Manager, NetApp users NEED SnapManager

Posted on by

This is a follow up to my recent post NetApp and EMC: Replication Management Tools Comparison, in which I discussed the differences between EMC Replication Manager and NetApp SnapManager.

————

As a former customer of both NetApp and EMC, and now as an employee of EMC, I noticed a big difference between NetApp and EMC as far as marketing their replication management tools. As a customer, EMC talked about Replication Manager several times and we purchased it and deployed it. NetApp made SnapManager a very central part of their sales campaign, sometimes skipping any discussion of the underlying storage in favor of showing off SnapManager functionality. This is an extremely effective sales technique and NetApp sales teams are so good at this that many people don’t even realize that other vendors have similar, and in my opinion EMC has better, functionality.  One of the reasons for this difference in marketing strategy is that NetApp users NEED SnapManager, while EMC users do not always need Replication Manager.

The reason why is both simple and complex…

EMC storage arrays (Clariion, Symmetrix, RecoverPoint, Invista) all have one technology in common that NetApp Filers do not–Consistency Groups. A consistency group allows the storage system to take a snapshot of multiple LUNs simultaneously, so simultaneous in fact that all of the snapshots are at the exact same point in time down to the individual write. This means that, without taking any applications offline and without any orchestration software, EMC storage arrays can create crash-consistent copies of nearly any kind of data at any time.

The EMC Whitepaper “EMC CLARiiON Database Storage Solutions: Oracle 10g/11g with CLARiiON Storage Replication Consistency” downloadable from EMC’s website has the following explanation of consistency groups in general…

“…Consistent replication operates on multiple LUNs as a set such that if the replication action fails for one member in the set, replication for all other members of the set are canceled or stopped.  Thus the contents of all replicated LUNs in the set are guaranteed to be identical point-in-time replicas of their source and dependent-write consistency is maintained…”

“…With consistent replication, the database does not have to be shut down or put into “hot backup mode.”  Replicates created with SnapView or MV/S (or MV/A, Timefinder, SRDF, Recoverpoint, etc) consistency operations, without first quiescing or halting the application, are restartable point-in-time replicas of the production data and guaranteed to be dependent-write consistent.”

Consistency is important for any application that is writing to multiple LUNs at the same time such as SQL database and log volumes. SnapManager and Replication Manager actually prepare the application by quiescing the database during the snapshot creation process. This process creates “application-consistent” copies which are technically better for recovery compared with “storage-consistent” copies (also known as crash-consistent copies).

So, while I will acknowledge that quiescing the database during a snapshot/replication operation provides the best possible recovery image, that may not be realistic in some scenarios.  The first issue is that the actual operation of quiescing, snapping, checking the image, then pushing an update to a remote storage array takes some time.  Depending on the size of the dataset, this operation can take from several minutes to several hours to complete.  If you have a Recovery Point Objective (RPO) of 5 minutes or less, using either of these tools is pretty much a non-starter.

Another issue is one of application support.  EMC Replication Manager and NetApp SnapManager have very wide support for the most popular operating systems, filesystems, databases, and applications, they certainly don’t support every application.  A very simple example is a Novell Netware file server with a NSS pool/volume spanning multiple LUNs.  Neither NetApp nor EMC have support for Novell Netware in their replication management tools.  While you can certainly replicate all of the LUNs with NetApp SnapManager, SnapManager has no consistency technology built-in to keep the LUNs write-order consistent.  The secondary copy will appear completely corrupt to the Netware server if a recovery is attempted.  Through the use of consistency groups with MirrorView/Async, the replication of each LUN is tracked as a group and all of the LUNs are write-order consistent with each other, keeping the filesystem itself consistent.  You would need to have either array-level consistency technology, or support for Netware in the replication management tool in order to replication such a server..  Unfortunately, NetApp provides neither.

You may have complex applications that consist of Oracle and SQL databases, NTFS filesystems, and application servers running as VMs.  Using array-based consistency groups, you can replicate all of these components simultaneously and keep them all consistent with each other.  This way you won’t have transactions that normally affect two databases end up missing in one of the two after a recovery operation, even if those databases are different technologies (Oracle and MySQL, or PostgreSQL for example).

EMC Storage arrays provide consistency group technology for Snapshots and Replication in Clariion and Symmetrix storage arrays.  In fact, with Symmetrix, consistency groups can span multiple arrays without any host software.  By comparison, NetApp Filers do not have consistency group technology in the array.  Snapshots are taken (for local replicas and for SnapMirror) at the FlexVolume level.  Two FlexVolumes cannot be snapped consistently with each other without SnapManager.

There are a couple workarounds for NetApp users–you can snapshot an aggregate, but that is not recommended by NetApp for most customers, or you can put multiple LUNs in the same FlexVol, but that still limits you to 16TB of data including snapshot reserve space, and both options violate best practices for database designs of keeping data and logs in separate spindles for recovery.  Even with these workarounds, you cannot gain LUN consistency across the two controllers in an HA Filer pair, something the CLARiiON does natively, and can help for load balancing IO across the storage processors.

In general, I recommend that EMC customers use EMC Replication Manager and NetApp customers use SnapManager for the applications that are supported, and for most scenarios.  But when RPO’s are short, or the environment falls outside the support matrix for those tools, consistency groups become the best or only option.

Incidentally, with EMC RecoverPoint, you get the best of both worlds.  CDP or near-CDP replication of data using consistency groups for zero or near-zero RPOs plus application-consistent bookmarks made anytime the database is quiesced.  Recovery is done from the up-to-the-second version of the data, but if that data is not good for any reason, you can roll back to another point in time, including a point-in-time when the database was quiesced (a bookmark).

So, while EMC has, in Replication Manager, an equivalent offering to NetApp’s SnapManager, EMC customers are not required to use it, and in some cases they can achieve better results using array-based consistency technologies.